Way:
Local/remote controlConfiguration:
3 units (2 in use and 1 as backup)Cycle:
2-4 monthsRange:
Water intake from reservoirs, rivers and lakesSize:
customizedQuality:
CCS marine steel plate1. The floating pump stations is connected by assembly, making production, transportation, and installation convenient and fast, and can meet the needs of various water intake sizes. The water intake system adopts advanced vacuum self suction method according to the water intake size and head height, and is composed of energy-saving variable frequency high and low voltage motors matched with double suction centrifugal pumps.
2. The ship's water supply pipeline system is connected to the fixed piers using special structural flexible joints, universal joints, and rotary joints, ensuring that the floating ship pump station can still maintain pressure and operate normally in the event of changes in water level.
3. The control system adopts intelligent design to achieve automated operation and remote control, with remote and local switching functions.
Structural features:
The horizontal rotary joint rocker arm is connected to the structural pump station, and a universal joint is installed at both ends of the water supply pipe. With the universal joint, it can rotate freely to adapt to the ups and downs, bumps, and swings of the ship's hull. It has higher water pressure resistance than rubber pipes and a longer service life.
Scan